SubjectRe: [PATCH] hid_sensor_magn_3d: Fix scale for rotation from north channels
Thanks for the review. I don't believe many devices have this problem
no need to rush it.

On Sun, Jul 19, 2015 at 7:57 AM, Jonathan Cameron <jic23@kernel.org> wrote:
> On 15/07/15 08:43, Reyad Attiyat wrote:
>> Some devices on a hid sensor hub will not report a measurement unit. This
>> causes the rotation from north channels to have an incorrect scale value.
>> This patch will set the unit to degrees if the maximum value is 360 when
>> the unit exponent value is accounted for.
>>
>> Signed-off-by: Reyad Attiyat <reyad.attiyat@gmail.com>
> Hmm. Ah well, another quirk to work around I guess.
>
> Looks fine to me. Would like an Ack from Srinivas though.
> Also this is a bit large and invasive to send on as a fix (as it's not
> a regression) so will need to wait for the next merge window.
> Can mark it as stable material though so it will filter back through
> in the long run.
>
> If there are lots of devices being broken by this, let me know and maybe
> we will try and see if Greg is happy to pass it on to Linus.
>
> Jonathan
>
>> ---
>> .../iio/common/hid-sensors/hid-sensor-attributes.c | 19 ++++++++++++++++
>> drivers/iio/magnetometer/hid-sensor-magn-3d.c | 26 +++++++++++++++++++++-
>> include/linux/hid-sensor-hub.h | 4 ++++
>> 3 files changed, 48 insertions(+), 1 deletion(-)
>>
>> diff --git a/drivers/iio/common/hid-sensors/hid-sensor-attributes.c b/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
>> index e81f434..3c79847 100644
>> --- a/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
>> +++ b/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
>> @@ -46,6 +46,7 @@ static struct {
>>
>> {HID_USAGE_SENSOR_COMPASS_3D, 0, 0, 1000},
>> {HID_USAGE_SENSOR_COMPASS_3D, HID_USAGE_SENSOR_UNITS_GAUSS, 1, 0},
>> + {HID_USAGE_SENSOR_COMPASS_3D, HID_USAGE_SENSOR_UNITS_DEGREES, 1, 0},
>>
>> {HID_USAGE_SENSOR_INCLINOMETER_3D, 0, 0, 17453},
>> {HID_USAGE_SENSOR_INCLINOMETER_3D,
>> @@ -317,6 +318,24 @@ static void adjust_exponent_micro(int *val0, int *val1, int scale0,
>> }
>> }
>>
>> +void hid_sensor_get_unit_expo_fraction(
>> + struct hid_sensor_hub_attribute_info *attr_info,
>> + int *num, int *denom)
>> +{
>> + s32 exp = hid_sensor_convert_exponent(attr_info->unit_expo);
>> +
>> + if (exp == 0) {
>> + *num = *denom = 1;
>> + } else if (exp < 0) {
>> + *num = 1;
>> + *denom = pow_10(abs(exp));
>> + } else if (exp > 0) {
>> + *num = pow_10(exp);
>> + *denom = 1;
>> + }
>> +}
>> +EXPORT_SYMBOL(hid_sensor_get_unit_expo_fraction);
>> +
>> int hid_sensor_format_scale(u32 usage_id,
>> struct hid_sensor_hub_attribute_info *attr_info,
>> int *val0, int *val1)
>> diff --git a/drivers/iio/magnetometer/hid-sensor-magn-3d.c b/drivers/iio/magnetometer/hid-sensor-magn-3d.c
>> index d8a0c8d..173d2f5 100644
>> --- a/drivers/iio/magnetometer/hid-sensor-magn-3d.c
>> +++ b/drivers/iio/magnetometer/hid-sensor-magn-3d.c
>> @@ -311,6 +311,7 @@ static int magn_3d_parse_report(struct platform_device *pdev,
>> int i;
>> int attr_count = 0;
>> struct iio_chan_spec *_channels;
>> + struct hid_sensor_hub_attribute_info *first_channel_attr_info;
>>
>> /* Scan for each usage attribute supported */
>> for (i = 0; i < MAGN_3D_CHANNEL_MAX; i++) {
>> @@ -389,9 +390,32 @@ static int magn_3d_parse_report(struct platform_device *pdev,
>> dev_dbg(&pdev->dev, "magn_3d Setup %d IIO channels\n",
>> *chan_count);
>>
>> + first_channel_attr_info = &(st->magn[_channels[0].address]);
>> +
>> + /* Try and set unit based off exponent, logical min and max */
>> + if (!first_channel_attr_info->units) {
>> + int num, denom;
>> + s32 log_min = first_channel_attr_info->logical_minimum;
>> + s32 log_max = first_channel_attr_info->logical_maximum;
>> +
>> + dev_dbg(&pdev->dev, "magn_3d Units not set. Unit Expo %d Logical Min: %d Max: %d\n",
>> + first_channel_attr_info->unit_expo,
>> + log_min, log_max);
>> +
>> + hid_sensor_get_unit_expo_fraction(first_channel_attr_info,
>> + &num, &denom);
>> +
>> + /* Check for unit Degrees */
>> + if (log_min == 0 && num == 1 && (log_max == 360 * denom)) {
>> + first_channel_attr_info->units =
>> + HID_USAGE_SENSOR_UNITS_DEGREES;
>> + dev_dbg(&pdev->dev, "magn_3d Set units to degrees.");
>> + }
>> +
>> + }
>> st->scale_precision = hid_sensor_format_scale(
>> HID_USAGE_SENSOR_COMPASS_3D,
>> - &st->magn[CHANNEL_SCAN_INDEX_X],
>> + first_channel_attr_info,
>> &st->scale_pre_decml, &st->scale_post_decml);
>>
>> /* Set Sensitivity field ids, when there is no individual modifier */
>> diff --git a/include/linux/hid-sensor-hub.h b/include/linux/hid-sensor-hub.h
>> index 0042bf3..627fd68 100644
>> --- a/include/linux/hid-sensor-hub.h
>> +++ b/include/linux/hid-sensor-hub.h
>> @@ -267,6 +267,10 @@ int hid_sensor_format_scale(u32 usage_id,
>> struct hid_sensor_hub_attribute_info *attr_info,
>> int *val0, int *val1);
>>
>> +void hid_sensor_get_unit_expo_fraction(
>> + struct hid_sensor_hub_attribute_info *attr_info,
>> + int *num, int *denom);
>> +
>> s32 hid_sensor_read_poll_value(struct hid_sensor_common *st);
>>
>> #endif
>>
>


\
 
 \ /