Messages in this thread | | | Date | Thu, 25 Jun 2015 10:56:15 +0530 | From | Vaibhav Hiremath <> | Subject | Re: [PATCH-v3 2/3] mfd: 88pm800: Allow configuration of interrupt clear method |
| |
On Thursday 25 June 2015 05:33 AM, Krzysztof Kozlowski wrote: > 2015-06-24 18:21 GMT+09:00 Vaibhav Hiremath <vaibhav.hiremath@linaro.org>: >> As per the spec, bit 1 (INT_CLEAR_MODE) of reg addr 0xe >> (page 0) controls the method of clearing interrupt >> status of 88pm800 family of devices; >> >> 0: clear on read >> 1: clear on write >> >> This patch allows to configure this field, through DT. >> >> Also, as suggested by "Lee Jones" renaming DT property and variable >> field to appropriate name. >> >> Signed-off-by: Zhao Ye <zhaoy@marvell.com> >> Signed-off-by: Vaibhav Hiremath <vaibhav.hiremath@linaro.org> > > It does not look like a property of the board. Instead it looks like a > runtime configuration so it should not be part of DT bindings. >
Why do you say that?
It is very well feature of 88PM860 device, where you can control irq clear operation (either read/write).
Thanks, Vaibhav
> I understand that previously this was configured by platform data and > now you want to move everything to DT. But this does not belong to > DT... >
Thats not completely true. I think DT is the right place for this configuration.