Messages in this thread Patch in this message | | | From | Adam Thomson <> | Date | Tue, 23 Sep 2014 11:53:46 +0100 | Subject | [PATCH 8/8] iio: Add ABI documentation for input current readings |
| |
Add information on in_current related readings.
Signed-off-by: Adam Thomson <Adam.Thomson.Opensource@diasemi.com> --- Documentation/ABI/testing/sysfs-bus-iio | 17 +++++++++++++++++ 1 file changed, 17 insertions(+)
diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio index d760b02..37cd4d4 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio +++ b/Documentation/ABI/testing/sysfs-bus-iio @@ -92,6 +92,18 @@ Description: is required is a consistent labeling. Units after application of scale and offset are millivolts.
+What: /sys/bus/iio/devices/iio:deviceX/in_currentY_raw +What: /sys/bus/iio/devices/iio:deviceX/in_currentY_supply_raw +KernelVersion: 3.17 +Contact: linux-iio@vger.kernel.org +Description: + Raw (unscaled no bias removal etc.) current measurement from + channel Y. In special cases where the channel does not + correspond to externally available input one of the named + versions may be used. The number must always be specified and + unique to allow association with event codes. Units after + application of scale and offset are milliamps. + What: /sys/bus/iio/devices/iio:deviceX/in_capacitanceY_raw KernelVersion: 3.2 Contact: linux-iio@vger.kernel.org @@ -227,6 +239,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_accel_y_offset What: /sys/bus/iio/devices/iio:deviceX/in_accel_z_offset What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_offset What: /sys/bus/iio/devices/iio:deviceX/in_voltage_offset +What: /sys/bus/iio/devices/iio:deviceX/in_currentY_offset +What: /sys/bus/iio/devices/iio:deviceX/in_current_offset What: /sys/bus/iio/devices/iio:deviceX/in_tempY_offset What: /sys/bus/iio/devices/iio:deviceX/in_temp_offset What: /sys/bus/iio/devices/iio:deviceX/in_pressureY_offset @@ -249,8 +263,11 @@ Description: to the _raw output.
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_scale +What: /sys/bus/iio/devices/iio:deviceX/in_currentY_scale What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_supply_scale +What: /sys/bus/iio/devices/iio:deviceX/in_currentY_supply_scale What: /sys/bus/iio/devices/iio:deviceX/in_voltage_scale +What: /sys/bus/iio/devices/iio:deviceX/in_current_scale What: /sys/bus/iio/devices/iio:deviceX/out_voltageY_scale What: /sys/bus/iio/devices/iio:deviceX/out_altvoltageY_scale What: /sys/bus/iio/devices/iio:deviceX/in_accel_scale -- 1.9.3
| |