Messages in this thread | | | Date | Wed, 16 Jul 2014 08:43:22 +0200 | From | Stefan Agner <> | Subject | Re: [PATCH v3 4/4] can: flexcan: add vf610 support for FlexCAN |
| |
Am 2014-07-15 16:24, schrieb Marc Kleine-Budde: <snip> >> @@ -150,18 +171,20 @@ >> * FLEXCAN hardware feature flags >> * >> * Below is some version info we got: >> - * SOC Version IP-Version Glitch- [TR]WRN_INT >> - * Filter? connected? >> - * MX25 FlexCAN2 03.00.00.00 no no >> - * MX28 FlexCAN2 03.00.04.00 yes yes >> - * MX35 FlexCAN2 03.00.00.00 no no >> - * MX53 FlexCAN2 03.00.00.00 yes no >> - * MX6s FlexCAN3 10.00.12.00 yes yes >> + * SOC Version IP-Version Glitch- [TR]WRN_INT Memory err >> + * Filter? connected? detection >> + * MX25 FlexCAN2 03.00.00.00 no no no >> + * MX28 FlexCAN2 03.00.04.00 yes yes no >> + * MX35 FlexCAN2 03.00.00.00 no no no >> + * MX53 FlexCAN2 03.00.00.00 yes no no >> + * MX6s FlexCAN3 10.00.12.00 yes yes no >> + * VF610 FlexCAN3 ? no no yes > ^^ ^^ > > Can you check the datasheet if the flexcan core has a "Glitch Filter > Width Register (FLEXCANx_GFWR)"
There is no such register called GFWR/Glitch Filter or similar.
> Can you check if the core generates a warning interrupt with the current > setup, if you don't switch on bus error reporting? This means internally > the [TR]WRN_INT is connected and works as specified.
Ok, so I disabled TWRNMSK (Bit 11) in the control register and printed out the error and status register (ESR1), this is what I get: [ 191.285295] flexcan_irq, esr=00040080 [ 191.288996] flexcan_irq, ctrl=17092051
Bit 17 (TWRNINT) is not set while TWRNMSK is disabled. Hence [TR]WRN_INT is not connected?
-- Stefan
| |