Messages in this thread | | | Date | Mon, 30 Jun 2014 15:49:09 +0200 | From | Tomasz Figa <> | Subject | Re: [PATCH] clk: s3c64xx: Hookup SPI clocks correctly |
| |
On 18.06.2014 11:52, Charles Keepax wrote: > In the move to this clock driver the hookups for the SPI clocks were > dropped, which causes my system Cragganmore (s3c6410 based) to be unable > to locate any spibus clocks. This patch adds them back in. > > When taking the clock from the epll clock (SCLK) the rates on the SPI > bus are incorrect, this needs further debugging but the hookup here > should be correct and the problem should be else where. > > The USBCLK case has been dropped because this requires the USB PHY to be > enabled. > > Signed-off-by: Charles Keepax <ckeepax@opensource.wolfsonmicro.com> > --- > drivers/clk/samsung/clk-s3c64xx.c | 6 ++++-- > 1 files changed, 4 insertions(+), 2 deletions(-)
Applied as a fix for 3.16.