lkml.org 
[lkml]   [2013]   [Dec]   [10]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
SubjectRe: [PATCH v1 1/6] net: mv643xx_eth: properly start/stop phy device
From
From: David Miller <davem@davemloft.net>
Date: Tue, 10 Dec 2013 21:52:53 -0500 (EST)

>
> This series looks good, applied to net-next, thanks.

Actually, I had to revert.

You cannot use late_initcall_sync() from code that is potentially
built modular, this caused my build to fail at the mdio_bus code.

drivers/net/phy/mdio_bus.c:344:1: warning: data definition has no type or storage class [enabled by default]
drivers/net/phy/mdio_bus.c:344:1: error: type defaults to ‘int’ in declaration of ‘late_initcall_sync’ [-Werror=implicit-int]
drivers/net/phy/mdio_bus.c:344:1: warning: parameter names (without types) in function declaration [enabled by default]
drivers/net/phy/mdio_bus.c:339:12: warning: ‘mdio_bus_class_suspend_unused’ defined but not used [-Wunused-function]
\
 
 \ /
  Last update: 2013-12-11 04:21    [W:0.156 / U:0.104 seconds]