Messages in this thread | | | Date | Mon, 24 Sep 2012 14:21:10 +0100 | From | Alan Cox <> | Subject | Re: [PATCH] Powerpc 8xx CPM_UART setting MAXIDL register proportionaly to baud rate |
| |
On Mon, 24 Sep 2012 08:39:44 +0200 Christophe Leroy <christophe.leroy@c-s.fr> wrote:
> MAXIDL is the timeout after which a receive buffer is closed when not > full if no more characters are received. We calculate it from the > baudrate so that the duration is always the same at standard rates: > about 4ms. At 9600 bauds it gives a timeout of 4 characters, which is > the timeout on the 8250 UART. > > Signed-off-by: Christophe Leroy <christophe.leroy@c-s.fr>
Looks good tome - series Acked-by: Alan Cox <alan@linux.intel.com>
| |