lkml.org 
[lkml]   [2012]   [Jun]   [19]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
From
SubjectRE: [PATCH v2] charger_manager: update charge profile upon temperature zone change
Date
> > On Mon, May 07, 2012 at 11:28:05PM +0530, Ramakrishna Pallala wrote:
> > > Battery vendors like UER suggest to program Low Charge Voltage in
> > > case of high or low temperatures. So a battery can have different
> > > charge profile with in the battery operating temperature limits.
> > >
> > > Next, there could be events like drop or rise in VBUS voltage in
> > > that case we might have to adjust the charge current to stabilize VBUS
> voltage.
> > >
> > > This patch allows the Charger-Manager to adjust the charging
> > > parameters upon events like VBUS rise or drop and allows batteries
> > > to have multiple charge profiles for different temperature zones.
> > >
> > > Signed-off-by: Ramakrishna Pallala <ramakrishna.pallala@intel.com>
> > > ---
> >
> > Applied, thanks a lot!
>
> Oh, actually. I see the feature is still under discussion. I really need some kind of
> OK/Ack from charger-manager folks before applying.

I will come with new patch once we come to a conclusion.

Thanks,
Ram
\
 
 \ /