lkml.org 
[lkml]   [2012]   [Jun]   [19]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH v2] charger_manager: update charge profile upon temperature zone change
On Mon, May 07, 2012 at 11:28:05PM +0530, Ramakrishna Pallala wrote:
> Battery vendors like UER suggest to program Low Charge Voltage in case
> of high or low temperatures. So a battery can have different charge profile
> with in the battery operating temperature limits.
>
> Next, there could be events like drop or rise in VBUS voltage in that case
> we might have to adjust the charge current to stabilize VBUS voltage.
>
> This patch allows the Charger-Manager to adjust the charging parameters
> upon events like VBUS rise or drop and allows batteries to have multiple
> charge profiles for different temperature zones.
>
> Signed-off-by: Ramakrishna Pallala <ramakrishna.pallala@intel.com>
> ---

Applied, thanks a lot!

--
Anton Vorontsov
Email: cbouatmailru@gmail.com


\
 
 \ /