Messages in this thread |  | | | Date | Mon, 11 Jun 2012 18:36:07 +0800 | | From | Mark Brown <> | | Subject | Re: [PATCH 08/22] regulator: Change ab8500 match names to reflect Device Tree |
| |
On Mon, Jun 11, 2012 at 11:27:53AM +0100, Lee Jones wrote: > On 05/06/12 11:38, Mark Brown wrote:
> >You're missing something - note what I say above about the direction the > >mapping is done in, and consider what happens if we've got two of the > >same PMIC down in a system.
> I'm still not seeing how this would cause an issue. The only Device > Tree nodes which will be parsed are the ones which are specified by > a particular driver's compatible string, meaning that any other > nodes referencing similar regulator/supply names would be ignored.
Suppose you have two devices of the same type with an array of name based regulators, meaning the nodes with constraints have to have a particular name in order to be matched to the regulator. How would a consumer reference a node to specify a supply? [unhandled content-type:application/pgp-signature] |  |