Messages in this thread |  | | | Date | Thu, 5 Apr 2012 11:37:06 +0100 | | From | Mark Brown <> | | Subject | Re: [PATCH] regulator: Support set_voltage_time_sel for drivers implement set_voltage |
| |
On Wed, Apr 04, 2012 at 10:32:10AM +0800, Axel Lin wrote: > In currently implementation of _regulator_do_set_voltage, set_voltage_time_sel will > only be called if set_voltage_sel is implemented. > > set_voltage_time_sel actually only needs get_voltage_sel to get old_selector.
Applied, thanks. [unhandled content-type:application/pgp-signature] |  |