    SubjectRe: dynamic LCD support for "embedded" systems
    > DVI monitor), and that EDID data just gets passed-through via the VGA
    > IC. so it's all the same stuff... so what's the damn difference
    > between a system with a VGA monitor and a system with the exact same
    > LCD panel *from* that VGA monitor, ehn? :) ok, rhetorical question.

    I'm not convinced it is the same stuff for various reaosns and bits of
    historical bug fixing and observation.

    > devicetree LCD modules. these could still be dynamically loaded,
    > right? i mean, it's a bit crazy, but you could have associated with a
    > particular LCD panel a devicetree-compliant dynamic loaded module
    > which had the correct LCD settings (including the required pre-tested
    > hsync and vsync data), right?

    In theory, or passed to the kernel at boot. The obvious long term path I
    would have thought would have been to move to 'device tree if data present
    else...' in the various panel drivers. That way there are no sudden bumps
    in the road for distributors but a device tree data set from any source
    would trump the data extracted by other means.


    \
     
     \ /