Messages in this thread | | | Subject | Re: [PATCH 2/2] power: bq20z75: enable detection after registering | From | Rhyland Klein <> | Date | Tue, 24 May 2011 12:07:33 -0700 |
| |
On Tue, 2011-05-24 at 12:06 -0700, Rhyland Klein wrote: > Need to enable detection, which is also blocking the unit conversion logic > after registering the power_supply. > > Signed-off-by: Rhyland Klein <rklein@nvidia.com> > --- > v2: This should have been adding the line, not removing it. Fixed that. > > drivers/power/bq20z75.c | 2 ++ > 1 files changed, 2 insertions(+), 0 deletions(-) > > diff --git a/drivers/power/bq20z75.c b/drivers/power/bq20z75.c > index e1adc0e..9c5e5be 100644 > --- a/drivers/power/bq20z75.c > +++ b/drivers/power/bq20z75.c > @@ -702,6 +702,8 @@ skip_gpio: > > INIT_DELAYED_WORK(&bq20z75_device->work, bq20z75_delayed_work); > > + bq20z75_device->enable_detection = true; > + > return 0; > > exit_psupply:
ignore this patch, sent updated patch with proper version tag in subject.
-rhyland
| |