Messages in this thread Patch in this message | | | Date | Wed, 2 Mar 2011 18:15:44 +0100 | From | Jean Delvare <> | Subject | [PATCH] bloat-o-meter: Include read-only data section in report |
| |
I'm not sure why the read-only data section is excluded from the report, it seems as relevant as the other data sections (b and d).
I've stripped the symbols starting with __mod_ as they can have their names dynamically generated and thus comparison between binaries is not possible.
Signed-off-by: Jean Delvare <khali@linux-fr.org> --- Disclaimer: I don't know anything about python.
scripts/bloat-o-meter | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-)
--- linux-2.6.38-rc6.orig/scripts/bloat-o-meter 2011-03-02 17:55:46.000000000 +0100 +++ linux-2.6.38-rc6/scripts/bloat-o-meter 2011-03-02 17:57:05.000000000 +0100 @@ -17,7 +17,9 @@ def getsizes(file): sym = {} for l in os.popen("nm --size-sort " + file).readlines(): size, type, name = l[:-1].split() - if type in "tTdDbB": + if type in "tTdDbBrR": + # strip generated symbols + if name[:6] == "__mod_": continue # function names begin with '.' on 64-bit powerpc if "." in name[1:]: name = "static." + name.split(".")[0] sym[name] = sym.get(name, 0) + int(size, 16)
-- Jean Delvare
| |