lkml.org 
[lkml]   [2011]   [Oct]   [5]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
    /
    From
    Date
    SubjectRe: [PATCH 2/2] regulator: Clarify documentation for regulator-regulator supplies

    Resend.

    Did not yet make it into linux next.

    On Sep 8, 2011, at 10:41 AM, Mark Brown wrote:

    > The mechanism used for connecting regulators together when one regulator
    > supplies another wasn't clear as the names being used weren't really tied
    > together well.
    >
    > Reported-by: Philip Rakity <prakity@marvell.com>
    > Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
    > ---
    > Documentation/power/regulator/machine.txt | 11 +++++++++--
    > 1 files changed, 9 insertions(+), 2 deletions(-)
    >
    > diff --git a/Documentation/power/regulator/machine.txt b/Documentation/power/regulator/machine.txt
    > index 311c61f..ce63af0 100644
    > --- a/Documentation/power/regulator/machine.txt
    > +++ b/Documentation/power/regulator/machine.txt
    > @@ -43,6 +43,7 @@ to their supply regulator :-
    >
    > static struct regulator_init_data regulator1_data = {
    > .constraints = {
    > + .name = "Regulator-1",
    > .min_uV = 3300000,
    > .max_uV = 3300000,
    > .valid_modes_mask = REGULATOR_MODE_NORMAL,
    > @@ -51,13 +52,19 @@ static struct regulator_init_data regulator1_data = {
    > .consumer_supplies = regulator1_consumers,
    > };
    >
    > +The name field should be set to something that is usefully descriptive
    > +for the board for configuration of supplies for other regulators and
    > +for use in logging and other diagnostic output. Normally the name
    > +used for the supply rail in the schematic is a good choice. If no
    > +name is provided then the subsystem will choose one.
    > +
    > Regulator-1 supplies power to Regulator-2. This relationship must be registered
    > with the core so that Regulator-1 is also enabled when Consumer A enables its
    > supply (Regulator-2). The supply regulator is set by the supply_regulator
    > -field below:-
    > +field below and co:-
    >
    > static struct regulator_init_data regulator2_data = {
    > - .supply_regulator = "regulator_name",
    > + .supply_regulator = "Regulator-1",
    > .constraints = {
    > .min_uV = 1800000,
    > .max_uV = 2000000,
    > --
    > 1.7.5.4
    >



    \
     
     \ /
      Last update: 2011-10-06 03:45    [W:0.027 / U:1.612 seconds]