| From | Paul Gortmaker <> | Subject | [34-longterm 161/260] ALSA: oxygen: fix analog capture on Claro halo cards | Date | Sun, 2 Jan 2011 02:17:37 -0500 |
| |
From: Erik J. Staab <ejs@insightbb.com>
commit 0873a5ae747847ee55a63db409dff3476e45bcd9 upstream.
On the HT-Omega Claro halo card, the ADC data must be captured from the second I2S input. Using the default first input, which isn't connected to anything, would result in silence.
Signed-off-by: Erik J. Staab <ejs@insightbb.com> Signed-off-by: Clemens Ladisch <clemens@ladisch.de> Signed-off-by: Takashi Iwai <tiwai@suse.de> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com> --- sound/pci/oxygen/oxygen.c | 4 ++++ 1 files changed, 4 insertions(+), 0 deletions(-)
diff --git a/sound/pci/oxygen/oxygen.c b/sound/pci/oxygen/oxygen.c index 289cb4d..6c0a11a 100644 --- a/sound/pci/oxygen/oxygen.c +++ b/sound/pci/oxygen/oxygen.c @@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip, chip->model.suspend = claro_suspend; chip->model.resume = claro_resume; chip->model.set_adc_params = set_ak5385_params; + chip->model.device_config = PLAYBACK_0_TO_I2S | + PLAYBACK_1_TO_SPDIF | + CAPTURE_0_FROM_I2S_2 | + CAPTURE_1_FROM_SPDIF; break; } if (id->driver_data == MODEL_MERIDIAN || -- 1.7.3.3
|