From
Subject[PATCH 1/6] serial8250: Mark console as CON_ANYTIME
Date
From: Peter Zijlstra <peterz@infradead.org>

While trying to debug a cpu-hotplug issue I noticed printk() stopped
working once the cpu got marked offline, since the 8250 serial console
doesn't have any per-cpu resources the CON_ANYTIME bit is the safe and
documented way to make it work again.

Signed-off-by: Peter Zijlstra <a.p.zijlstra@chello.nl>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
---
drivers/serial/8250.c | 2 +-
1 files changed, 1 insertions(+), 1 deletions(-)

diff --git a/drivers/serial/8250.c b/drivers/serial/8250.c
index 4d8e14b..09a5508 100644
--- a/drivers/serial/8250.c
+++ b/drivers/serial/8250.c
@@ -2872,7 +2872,7 @@ static struct console serial8250_console = {
.device = uart_console_device,
.setup = serial8250_console_setup,
.early_setup = serial8250_console_early_setup,
- .flags = CON_PRINTBUFFER,
+ .flags = CON_PRINTBUFFER | CON_ANYTIME,
.index = -1,
.data = &serial8250_reg,
};
--
1.7.1


\
 
 \ /