lkml.org 
[lkml]   [2010]   [Oct]   [22]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
    Patch in this message
    /
    Date
    From
    Subject[03/66] ALSA: oxygen: fix analog capture on Claro halo cards
    2.6.32-stable review patch.  If anyone has any objections, please let us know.

    ------------------

    From: Erik J. Staab <ejs@insightbb.com>

    commit 0873a5ae747847ee55a63db409dff3476e45bcd9 upstream.

    On the HT-Omega Claro halo card, the ADC data must be captured from the
    second I2S input. Using the default first input, which isn't connected
    to anything, would result in silence.

    Signed-off-by: Erik J. Staab <ejs@insightbb.com>
    Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
    Signed-off-by: Takashi Iwai <tiwai@suse.de>
    Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>

    ---
    sound/pci/oxygen/oxygen.c | 4 ++++
    1 file changed, 4 insertions(+)

    --- a/sound/pci/oxygen/oxygen.c
    +++ b/sound/pci/oxygen/oxygen.c
    @@ -393,6 +393,10 @@ static int __devinit get_oxygen_model(st
    chip->model.suspend = claro_suspend;
    chip->model.resume = claro_resume;
    chip->model.set_adc_params = set_ak5385_params;
    + chip->model.device_config = PLAYBACK_0_TO_I2S |
    + PLAYBACK_1_TO_SPDIF |
    + CAPTURE_0_FROM_I2S_2 |
    + CAPTURE_1_FROM_SPDIF;
    break;
    }
    if (id->driver_data == MODEL_MERIDIAN ||



    \
     
     \ /
      Last update: 2010-10-22 20:57    [W:0.024 / U:0.096 seconds]