Hello,

Thomas Fjellstrom wrote:
> I have the same issue with a single WD 2TB Green drive. Technically two, but
> it always only gets errors from the same drive, so I was assuming it was the
> drive. I only have to setup the raid0 array, and put some light load on it for
> the kernel to start complaining, and eventually it just kicks the drive
> completely with the following messages:
>
> sd 3:0:0:0: [sdb] Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
> end_request: I/O error, dev sdb, sector 202026972
>
> The drive does work fine prior to the frozen timeout errors. And I was using
> it in windows (same raid0 config) just fine with no errors what so ever.

Can you post full dmesg output? The above doesn't tell much about ATA
side of things.

Thanks.

--