    On Mon, 27 Jul 2009 21:46:14 +0100, Mark Brown wrote:
    > On Mon, Jul 27, 2009 at 09:44:19PM +0200, Jean Delvare wrote:
    > > On Mon, 27 Jul 2009 14:46:02 +0100, Mark Brown wrote:
    > > > +#define WM831X_NAMED_VOLTAGE(id, name) \
    > > > + static SENSOR_DEVICE_ATTR(in##id##_input, S_IRUGO, show_voltage,\
    > > > + NULL, name); \
    > >
    > > I guess you could just call WM831X_VOLTAGE(id, name).
    >
    > That clashes with the unnamed voltage above. I could also call them
    > _NAMED and _UNNAMED, I suppose.

    Sorry for not being clear. I simply meant you could write the following:

    define WM831X_VOLTAGE(id, name) \
    static SENSOR_DEVICE_ATTR(in##id##_input, S_IRUGO, show_voltage, \
    NULL, name)

    #define WM831X_NAMED_VOLTAGE(id, name) \
    WM831X_VOLTAGE(id, name); \
    static SENSOR_DEVICE_ATTR(in##id##_label, S_IRUGO, show_label, \
    NULL, name)

    Which makes it more obvious that WM831X_NAMED_VOLTAGE is WM831X_VOLTAGE
    + label. But it's really up to you which way you prefer.

    --
    Jean Delvare


    \
     
     \ /