On Mon, 27 Jul 2009 21:46:14 +0100, Mark Brown wrote:
> On Mon, Jul 27, 2009 at 09:44:19PM +0200, Jean Delvare wrote:
> > On Mon, 27 Jul 2009 14:46:02 +0100, Mark Brown wrote:
> > > +#define WM831X_NAMED_VOLTAGE(id, name) \
> > > + static SENSOR_DEVICE_ATTR(in##id##_input, S_IRUGO, show_voltage,\
> > > + NULL, name); \
> >
> > I guess you could just call WM831X_VOLTAGE(id, name).
>
> That clashes with the unnamed voltage above. I could also call them
> _NAMED and _UNNAMED, I suppose.

Sorry for not being clear. I simply meant you could write the following:

define WM831X_VOLTAGE(id, name) \
static SENSOR_DEVICE_ATTR(in##id##_input, S_IRUGO, show_voltage, \
NULL, name)

#define WM831X_NAMED_VOLTAGE(id, name) \
WM831X_VOLTAGE(id, name); \
static SENSOR_DEVICE_ATTR(in##id##_label, S_IRUGO, show_label, \
NULL, name)

Which makes it more obvious that WM831X_NAMED_VOLTAGE is WM831X_VOLTAGE
+ label. But it's really up to you which way you prefer.

--