SubjectRe: [Patch] acerhdf: Return temperature in milidegree
On Mon, Oct 19, 2009 at 11:11:07PM +0200, Peter Feuerer wrote:
> I just had a look at the documentation concerning this topic:
>
> Documentation/thermal/sysfs-api.txt:162
>
> temp Current temperature as reported by thermal zone (sensor)
> Unit: millidegree Celsius
> RO
> Required
>
>
> It is expected to be in millidegree, so I think we should discuss,
> modify and apply the patch.

Well well, looka here, it is an interface! I guess the temperature has
to be in millidegrees for better granularity or similar. Now userspace
has to do temp / 1000.0 and so on.

In that case, the patch should be applied. I'll give it a run later.

Minor nitpick: Add the sysfs-api requirement to the commit message
instead of "userspace applications."

Thanks.

--