Messages in this thread | | | From | Marcin Hlybin <> | Subject | Re: 3ware 8006-2LP on Linux 2.6 drive error, seagate disks | Date | Fri, 12 May 2006 15:43:31 +0200 |
| |
On Wednesday 26 of April 2006 17:32, Marcin Hlybin wrote:
> Apr 26 15:07:10 krenn kernel: 3w-xxxx: scsi2: Command failed: status = 0xc7, > flags = 0xc, unit #0.
Ok, I've solved my problem by changing SATA cables. I have tested controller with massive I/O operations with both enabled and disabled write-caching. Admittedly next day TK server crashed with NMI, parity errors and so on, but now I have new mainboard, new riser and everything works just fine. I use tw_cli to maintain the RAID.
Regards
-- Marcin Hlybin, marcin.hlybin (at) swmind.com Sys/Net Administrator, tel. +48 12 2523 402
SoftwareMind, www.softwaremind.pl | Where quality meets the future - To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/
| |