Messages in this thread |
Hi, On Fri, 23 Sep 2005, Paul E. McKenney wrote: > I believe Thomas is concerned about workloads that need a short-term > stable timebase. For example, a process-control application might need > to accurately measure a (say) 1500-millisecond time interval. Both > user-programmability and NTP adjustments to a given timebase could > destroy the needed measurement accuracy. NTP adjustments a quite small and not applied all at once, this means as soon as the time is synchronized, we could switch CLOCK_MONOTONIC to it. bye, Roman - To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/ | ||||||||||||
| Last update: 2005-09-24 03:43 [from the cache] ©2003-2008 | |||||||||||||