    Hi,

    On Fri, 23 Sep 2005, Paul E. McKenney wrote:

    > I believe Thomas is concerned about workloads that need a short-term
    > stable timebase. For example, a process-control application might need
    > to accurately measure a (say) 1500-millisecond time interval. Both
    > user-programmability and NTP adjustments to a given timebase could
    > destroy the needed measurement accuracy.

    NTP adjustments a quite small and not applied all at once, this means as
    soon as the time is synchronized, we could switch CLOCK_MONOTONIC to it.

    bye, Roman
    -