lkml.org 
[lkml]   [2005]   [Sep]   [23]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [ANNOUNCE] ktimers subsystem
Hi,

On Fri, 23 Sep 2005, Paul E. McKenney wrote:

> I believe Thomas is concerned about workloads that need a short-term
> stable timebase. For example, a process-control application might need
> to accurately measure a (say) 1500-millisecond time interval. Both
> user-programmability and NTP adjustments to a given timebase could
> destroy the needed measurement accuracy.

NTP adjustments a quite small and not applied all at once, this means as
soon as the time is synchronized, we could switch CLOCK_MONOTONIC to it.

bye, Roman
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/

\
 
 \ /
  Last update: 2005-09-24 05:43    [from the cache]