Messages in this thread | | | Date | Wed, 21 Dec 2005 23:07:25 +0100 | From | Jean Delvare <> | Subject | Re: Sensors errors with 15-rc6, 15-rc5 was normal |
| |
Hi Gene,
Please keep this conversation on the LKML, where it started.
> > Are you getting the temperature value from ACPI, or from a hwmon > > driver? If the latter, which driver is this, and which hardware > > monitoring chip do you have? > > Its coming from whatever source gkrellm-2.1.28 uses as the default src > for this, selecting other src's results in -200F or more readings. > Rebooting back to -rc5, the readings are normal but creeping up, about > 152F right now.
That's hardly helpful. If gkrellm doesn't tell you where the data comes from, we just can't use it to debug any issue. Please use "sensors" instead.
> >From sensors-detect: > Probing for `Winbond W83627HF' > Trying address 0x0290... Success! > (confidence 8, driver `w83781d') > > What else?
This is only one part of sensors-detect. I guess it then suggests the w83627hf driver instead. Which driver are you using, w83627hf or w83781d?
Please provide:
1* The complete output of sensors-detect.
2* The output of "sensors" in 2.6.15-rc5.
3* The output of "sensors" in 2.6.15-rc6.
4* The diff of your 2.6.15-rc5 kernel config file and 2.6.15-rc6 kernel config file.
Thanks, -- Jean Delvare - To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/
| |