Messages in this thread | | | Date | Fri, 27 Jun 2003 20:01:59 -0400 (EDT) | From | Mike Dresser <> | Subject | Re: bkbits.net is down |
| |
On Fri, 27 Jun 2003, Larry McVoy wrote:
> Anyone know what this means? This is from the supposedly superduper > rackspace machine which has a Mylex SCSI RAID (see below): > > DAC960#0: Physical Device 0:0 Sense Data Received > DAC960#0: Physical Device 0:0 Request Sense: Sense Key = 3, ASC = 11, ASCQ = 00 > DAC960#0: Physical Device 0:0 Request Sense: Information = 0380A6CA 00000000 > DAC960#0: Physical Device 0:0 Sense Data Received > DAC960#0: Physical Device 0:0 Request Sense: Sense Key = 3, ASC = 11, ASCQ = 00 > DAC960#0: Physical Device 0:0 Request Sense: Information = 0380A6CA 00000000 > DAC960#0: Physical Device 0:0 Errors: Parity = 0, Soft = 0, Hard = 0, Misc = 0 > DAC960#0: Physical Device 0:0 Errors: Timeouts = 0, Retries = 0, Aborts = 0, Predicted = 0
3h - MEDIUM ERROR: indicates that the command terminated with a non-recovered error caused by a flaw in the medium (the medium depends on the device type)
Have to lookup the asc and ascq with ibm, as it varies by manufacturer.
0Bh 01h DTLPWRSOMCAE Warning - specified temperature exceeded
My guess is that you're seeing a temperature warning on a drive.
Which makes sense with the overheated server room.
Mike