lkml.org 
[lkml]   [2002]   [Apr]   [10]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
    /
    Date
    From
    SubjectRAID superblock confusion
      Hi, all. I've found the following (vexing) problem with the way the
    raid code handles superblocks/migrating devices. This was with
    2.4.19-pre6. This machine has 7 SCSI controllers: 4 isp2x00 (qlogicfc)
    and 3 sym53c8xxx. On 3 of the isp2x00 controllers, there are 2 drives
    each. The second partition on each of these 6 drives forms part of the
    RAID0 set. The sym53c8xx driver is built into the kernel, always (it
    has the boot drive).

    If the isp2x00 driver is built-in to the kernel, then host numbers
    [0-3] are assigned to the isp2x00 controllers, and [4-6] to the
    sym53c8xx controllers. The devices on the isp2x00 controllers are
    detected first, which means they have lower minor numbers. This is
    configuration used when the RAID set was configured many moons ago,
    and continues to work.

    If the isp2x00 driver is built as a module, and the scsihosts boot
    parameter is passed to the kernel to reserve host numbers [0-3] for
    the isp2x00 controllers, then the RAID code gets confused. Even though
    the host numbers are the same, the device detection order is changed,
    and thus the minor numbers are changed. Even though I'm using
    persistent superblockss, which is supposed to allow one to move
    devices from one controller to another, I can't use my RAID) set in
    this configuration. Looks like a bug.

    Below is some relevant information.

    Kernel log for first (working) configuration:
    ===============================================================================
    [events: 0000004a]
    [events: 0000004a]
    [events: 0000004a]
    [events: 0000004a]
    [events: 0000004a]
    [events: 0000004a]
    md: autorun ...
    md: considering scsi/host2/bus0/target2/lun0/part2 ...
    md: adding scsi/host2/bus0/target2/lun0/part2 ...
    md: adding scsi/host2/bus0/target1/lun0/part2 ...
    md: adding scsi/host1/bus0/target2/lun0/part2 ...
    md: adding scsi/host1/bus0/target1/lun0/part2 ...
    md: adding scsi/host0/bus0/target2/lun0/part2 ...
    md: adding scsi/host0/bus0/target1/lun0/part2 ...
    md: created md0
    md: bind<scsi/host0/bus0/target1/lun0/part2,1>
    md: bind<scsi/host0/bus0/target2/lun0/part2,2>
    md: bind<scsi/host1/bus0/target1/lun0/part2,3>
    md: bind<scsi/host1/bus0/target2/lun0/part2,4>
    md: bind<scsi/host2/bus0/target1/lun0/part2,5>
    md: bind<scsi/host2/bus0/target2/lun0/part2,6>
    md: running: <scsi/host2/bus0/target2/lun0/part2><scsi/host2/bus0/target1/lun0/part2><scsi/host1/bus0/target2/lun0/part2><scsi/host1/bus0/target1/lun0/part2><scsi/host0/bus0/target2/lun0/part2><scsi/host0/bus0/target1/lun0/part2>
    md: scsi/host2/bus0/target2/lun0/part2's event counter: 0000004a
    md: scsi/host2/bus0/target1/lun0/part2's event counter: 0000004a
    md: scsi/host1/bus0/target2/lun0/part2's event counter: 0000004a
    md: scsi/host1/bus0/target1/lun0/part2's event counter: 0000004a
    md: scsi/host0/bus0/target2/lun0/part2's event counter: 0000004a
    md: scsi/host0/bus0/target1/lun0/part2's event counter: 0000004a
    md0: max total readahead window set to 1536k
    md0: 6 data-disks, max readahead per data-disk: 256k
    raid0: looking at scsi/host0/bus0/target1/lun0/part2
    raid0: comparing scsi/host0/bus0/target1/lun0/part2(11767488) with scsi/host0/bus0/target1/lun0/part2(11767488)
    raid0: END
    raid0: ==> UNIQUE
    raid0: 1 zones
    raid0: looking at scsi/host0/bus0/target2/lun0/part2
    raid0: comparing scsi/host0/bus0/target2/lun0/part2(11767488) with scsi/host0/bus0/target1/lun0/part2(11767488)
    raid0: EQUAL
    raid0: looking at scsi/host1/bus0/target1/lun0/part2
    raid0: comparing scsi/host1/bus0/target1/lun0/part2(11767488) with scsi/host0/bus0/target1/lun0/part2(11767488)
    raid0: EQUAL
    raid0: looking at scsi/host1/bus0/target2/lun0/part2
    raid0: comparing scsi/host1/bus0/target2/lun0/part2(11767488) with scsi/host0/bus0/target1/lun0/part2(11767488)
    raid0: EQUAL
    raid0: looking at scsi/host2/bus0/target1/lun0/part2
    raid0: comparing scsi/host2/bus0/target1/lun0/part2(11767488) with scsi/host0/bus0/target1/lun0/part2(11767488)
    raid0: EQUAL
    raid0: looking at scsi/host2/bus0/target2/lun0/part2
    raid0: comparing scsi/host2/bus0/target2/lun0/part2(11767488) with scsi/host0/bus0/target1/lun0/part2(11767488)
    raid0: EQUAL
    raid0: FINAL 1 zones
    raid0: zone 0
    raid0: checking scsi/host0/bus0/target1/lun0/part2 ... contained as device 0
    (11767488) is smallest!.
    raid0: checking scsi/host0/bus0/target2/lun0/part2 ... contained as device 1
    raid0: checking scsi/host1/bus0/target1/lun0/part2 ... contained as device 2
    raid0: checking scsi/host1/bus0/target2/lun0/part2 ... contained as device 3
    raid0: checking scsi/host2/bus0/target1/lun0/part2 ... contained as device 4
    raid0: checking scsi/host2/bus0/target2/lun0/part2 ... contained as device 5
    raid0: zone->nb_dev: 6, size: 70604928
    raid0: current zone offset: 11767488
    raid0: done.
    raid0 : md_size is 70604928 blocks.
    raid0 : conf->smallest->size is 70604928 blocks.
    raid0 : nb_zone is 1.
    raid0 : Allocating 8 bytes for hash.
    md: updating md0 RAID superblock on device
    md: scsi/host2/bus0/target2/lun0/part2 [events: 0000004b]<6>(write) scsi/host2/bus0/target2/lun0/part2's sb offset: 11767488
    md: scsi/host2/bus0/target1/lun0/part2 [events: 0000004b]<6>(write) scsi/host2/bus0/target1/lun0/part2's sb offset: 11767488
    md: scsi/host1/bus0/target2/lun0/part2 [events: 0000004b]<6>(write) scsi/host1/bus0/target2/lun0/part2's sb offset: 11767488
    md: scsi/host1/bus0/target1/lun0/part2 [events: 0000004b]<6>(write) scsi/host1/bus0/target1/lun0/part2's sb offset: 11767488
    md: scsi/host0/bus0/target2/lun0/part2 [events: 0000004b]<6>(write) scsi/host0/bus0/target2/lun0/part2's sb offset: 11767488
    md: scsi/host0/bus0/target1/lun0/part2 [events: 0000004b]<6>(write) scsi/host0/bus0/target1/lun0/part2's sb offset: 11767488
    md: ... autorun DONE.
    ===============================================================================

    Kernel log for second (failing) configuration:
    ===============================================================================
    [events: 0000004a]
    md: can not import scsi/host6/bus0/target0/lun0/part2, has active inodes!
    md: could not import scsi/host6/bus0/target0/lun0/part2, trying to run array nevertheless.
    [events: 0000004a]
    [events: 0000004a]
    [events: 0000004a]
    [events: 0000004a]
    md: autorun ...
    md: considering scsi/host2/bus0/target1/lun0/part2 ...
    md: adding scsi/host2/bus0/target1/lun0/part2 ...
    md: adding scsi/host1/bus0/target2/lun0/part2 ...
    md: adding scsi/host1/bus0/target1/lun0/part2 ...
    md: adding scsi/host0/bus0/target2/lun0/part2 ...
    md: adding scsi/host0/bus0/target1/lun0/part2 ...
    md: created md0
    md: bind<scsi/host0/bus0/target1/lun0/part2,1>
    md: bind<scsi/host0/bus0/target2/lun0/part2,2>
    md: bind<scsi/host1/bus0/target1/lun0/part2,3>
    md: bind<scsi/host1/bus0/target2/lun0/part2,4>
    md: bind<scsi/host2/bus0/target1/lun0/part2,5>
    md: running: <scsi/host2/bus0/target1/lun0/part2><scsi/host1/bus0/target2/lun0/part2><scsi/host1/bus0/target1/lun0/part2><scsi/host0/bus0/target2/lun0/part2><scsi/host0/bus0/target1/lun0/part2>
    md: scsi/host2/bus0/target1/lun0/part2's event counter: 0000004a
    md: scsi/host1/bus0/target2/lun0/part2's event counter: 0000004a
    md: scsi/host1/bus0/target1/lun0/part2's event counter: 0000004a
    md: scsi/host0/bus0/target2/lun0/part2's event counter: 0000004a
    md: scsi/host0/bus0/target1/lun0/part2's event counter: 0000004a
    md: device name has changed from scsi/host1/bus0/target2/lun0/part2 to scsi/host2/bus0/target1/lun0/part2 since last import!
    md: device name has changed from scsi/host1/bus0/target1/lun0/part2 to scsi/host1/bus0/target2/lun0/part2 since last import!
    md: device name has changed from scsi/host0/bus0/target2/lun0/part2 to scsi/host1/bus0/target1/lun0/part2 since last import!
    md: device name has changed from scsi/host0/bus0/target1/lun0/part2 to scsi/host0/bus0/target2/lun0/part2 since last import!
    md: device name has changed from scsi/host6/bus0/target0/lun0/part2 to scsi/host0/bus0/target1/lun0/part2 since last import!
    md0: former device scsi/host2/bus0/target1/lun0/part2 is unavailable, removing from array!
    md0: max total readahead window set to 1536k
    md0: 6 data-disks, max readahead per data-disk: 256k
    md: md0, array needs 6 disks, has 5, aborting.
    raid0: disks are not ordered, aborting!
    md: pers->run() failed ...
    md :do_md_run() returned -22
    md: md0 stopped.
    md: unbind<scsi/host2/bus0/target1/lun0/part2,4>
    md: export_rdev(scsi/host2/bus0/target1/lun0/part2)
    md: unbind<scsi/host1/bus0/target2/lun0/part2,3>
    md: export_rdev(scsi/host1/bus0/target2/lun0/part2)
    md: unbind<scsi/host1/bus0/target1/lun0/part2,2>
    md: export_rdev(scsi/host1/bus0/target1/lun0/part2)
    md: unbind<scsi/host0/bus0/target2/lun0/part2,1>
    md: export_rdev(scsi/host0/bus0/target2/lun0/part2)
    md: unbind<scsi/host0/bus0/target1/lun0/part2,0>
    md: export_rdev(scsi/host0/bus0/target1/lun0/part2)
    md: ... autorun DONE.
    ===============================================================================
    Note the following line from the kernel logs above:
    md: can not import scsi/host6/bus0/target0/lun0/part2, has active inodes!

    Well, that's no surprise, as this partition has /usr! And this
    partition isn't even mentioned in the /etc/raidtab file. But I note
    that it has the same device number in this (the broken) configuration
    as /dev/sd/c0b0t1u0p2 has in the working configuration.

    The /etc/raidtab file:
    ===============================================================================
    raiddev /dev/md/0
    raid-level 0
    nr-raid-disks 6
    persistent-superblock 1
    chunk-size 4
    device /dev/sd/c0b0t1u0p2
    raid-disk 0
    device /dev/sd/c0b0t2u0p2
    raid-disk 1
    device /dev/sd/c1b0t1u0p2
    raid-disk 2
    device /dev/sd/c1b0t2u0p2
    raid-disk 3
    device /dev/sd/c2b0t1u0p2
    raid-disk 4
    device /dev/sd/c2b0t2u0p2
    raid-disk 5
    ===============================================================================

    Regards,

    Richard....
    Permanent: rgooch@atnf.csiro.au
    Current: rgooch@ras.ucalgary.ca
    -
    To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
    the body of a message to majordomo@vger.kernel.org
    More majordomo info at http://vger.kernel.org/majordomo-info.html
    Please read the FAQ at http://www.tux.org/lkml/

    \
     
     \ /
      Last update: 2005-03-22 13:25    [W:0.045 / U:0.192 seconds]