    SubjectRe: SCSI scanner problem with all kernels since 2.3.42
    On Tue, Jan 09, 2001 at 03:53:02PM -0500, Douglas Gilbert wrote:

    > by timeouts ** resulting in scsi bus resets. Anyway the problem
    > seems to disappear with the recently released SANE 1.0.4 .
    > [The original report was based on SANE 1.0.3 and earlier.]

    In fact my report that the problem went away was wrong. :-(

    > ** SANE's newer sg interface shortens the per command timeout
    > from 10 minutes to 10 seconds. Most other OSes interfaces in
    > SANE have a timeout value of 1 minute or more. I suspect 10
    > seconds may be too short.

    Increasing the timeout fixed the problem.