lkml.org 
[lkml]   [2000]   [Mar]   [6]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: 3c59x & Cat 4003 Ethernet Lockups
Luuk van der Duim wrote:
>
> Mr. Mendelson,
>
> Does your 3c905B share an interrupt with another device?

/proc/pci doesn't show any conflicts, but I'm not directly in front of
any of the machines so I can't reboot them and see what BIOS wants to
map devices to.

Bus 0, device 9, function 0:
Ethernet controller: 3Com 3C905B 100bTX (rev 48).
Medium devsel. IRQ 17. Master Capable. Latency=64. Min Gnt=10.Max
Lat=10.
I/O at 0xd400 [0xd401].
Non-prefetchable 32 bit memory at 0xe8000000 [0xe8000000].
3Com 3c90x Version 1.0.0e 1999 <linux_drivers@3com.com>

When Donald Becker's driver is loaded, it looks like:

3c59x.c:v0.99H 11/17/98 Donald Becker
http://cesdis.gsfc.nasa.gov/linux/drivers/vortex.html
eth0: 3Com 3c905B Cyclone 100baseTx at 0xd400, 00:10:5a:83:df:19, IRQ
17
8K byte-wide RAM 5:3 Rx:Tx split, autoselect/Autonegotiate interface.
MII transceiver found at address 24, status 786d.
MII transceiver found at address 0, status 786d.
Enabling bus-master transmits and whole-frame receives.

Jordan Mendelson
Napster, Inc.

-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.rutgers.edu
Please read the FAQ at http://www.tux.org/lkml/

\
 
 \ /
  Last update: 2005-03-22 13:56    [from the cache]